telemed
Direct-read pipeline for Telemed ultrasound .tvd recordings — HDF5
metadata + per-panel mp4 with inner-image autocrop.
Extracts .tvd recordings to HDF5 sidecars via the AutoInt1 COM API,
then encodes to mp4 for downstream DLC / DUSTrack consumption. This
document is a reference for the design decisions baked into the
package; the per-function docstrings cover the surface in detail.
Install
pip install telemed
The Windows-only pywin32 dependency (required by the .tvd → .tvd.h5
extract path, which talks to EchoWave via COM) installs automatically
on Windows and is skipped on macOS / Linux. Non-Windows installs still
get the encode + analyze paths (export_video, process() over Set B
.tvd.h5 inputs, Log), they just can’t run COM extraction.
ffmpeg must be on PATH (used for the h265 encode).
Extract-path prerequisites (export_h5 / process)
Reading .tvd files goes through EchoWave’s AutoInt1 COM server, so
beyond pip install telemed the extract path additionally needs, on
the Windows machine that has the device software:
Echo Wave II installed (the Telemed vendor application). The COM server ships inside it — there’s nothing to download separately.
A one-time COM registration of the AutoInt1 ProgID — run
AutoInt1_regasm.batfrom an Administrator PowerShell (full command below).Admin EchoWave II + Admin Python per session (COM ROT publication is per-elevation — a non-elevated client can’t see an elevated server).
Full step-by-step in Per-session setup
below. The encode + analyze paths (export_video, Log,
process() over already-extracted .tvd.h5 files) need none of this —
just the pip install + ffmpeg.
Quickstart
import telemed
# Start EchoWave II as Administrator first; start your Python
# session as Administrator too. (COM ROT is per-elevation.)
telemed.process(r"M:/data/pia02")
# Equivalent to:
# telemed.export_h5(r"M:/data/pia02") # tvd -> tvd.h5 (Admin + EchoWave)
# telemed.export_video(r"M:/data/pia02") # tvd.h5 -> mp4(s) (offline)
# Inspect a single recording:
lf = telemed.Log("M:/data/pia02/scan.tvd.h5")
lf.view() # matplotlib browser, with scale bar
lf.to_video() # single-recording mp4 encode
Pipeline
.tvd --[COM via AutoInt1]--> .tvd.h5 --[ffmpeg]--> .mp4(s)
export_h5 export_video
Admin EchoWave required offline (no EchoWave)
process() chains both stages on the same source. All three accept a
file, folder, or iterable; recursive=True by default; idempotent
under skip_existing=True (default).
HDF5 schema (v1)
Composite suffix <stem>.tvd.h5 so downstream glob walks (*.tvd.h5)
catch them without picking up unrelated HDF5 data.
Root attributes (flat – no nested groups):
n_frames,full_frame_width,full_frame_heightn_b_images– count of active B-mode panels (1 = single probe; 2 = dual probe; up to 4)source_tvd_path,extracted_at_iso,schema_version="v1"image_dx_cm_per_px,image_dy_cm_per_px– display scale derived fromb_depth_mm / 10 / panel_height_px(Telemed support’s “trust the depth setting” calibration). Skipped ifb_depthwasn’t captured.Per active img_id N ∈ {1, 2, 3, 4} (1=B, 2=B2, 3=B3, 4=B4):
roi{N}_x1,roi{N}_x2,roi{N}_y1,roi{N}_y2(1-based pixel coords matching AutoInt1’s convention)roi{N}_width,roi{N}_height(inclusive pixel counts)physical_dx{N}_cm_per_px,physical_dy{N}_cm_per_px(beamformer-native scale – see “scale” note below)
param_*– opportunistic ParamGet sweep (~36 fields per recording on real EchoWave acquisitions): probe / beamformer identity, cine end timestamp, B-mode acquisition (depth, frequency, gain, dynamic range, focus, THI, frame averaging, …), geometry / orientation (scan-direction-changed, rotate, view-area, scan-type, …), sanity probes (file-opened, scanning-state, probe-active).
Inner-image autocrop bounds are NOT in the schema. The encoder detects the inner ultrasound image (depth ruler / margins / tick row stripped) from frame pixels at encode time – see “Inner-image autocrop” below. Keeping the bounds out of the sidecar means a detector tweak only requires a re-encode (offline), not a re-extract (Admin EchoWave).
Datasets:
/timing/frame_idx_1n– int32 (N,)/timing/time_ms– float64 (N,), frame 0 anchored at 0.0 ms/timing/ifi_ms– float64 (N,), inter-frame intervals/frames/gray– uint8 (N, H, W), full-frame display capture (omit by passingframes=Falsefor a fast timing-only extract)
Schema history
version |
date |
change |
|---|---|---|
v1 |
2026-05-24 |
initial public release. Consolidates the |
in-development |
||
multi-ROI / display-scale capture) into one labelled baseline. |
Log reads both the public v1 label and the legacy in-development
labels (v1a{1..5}) transparently, so on-disk sidecars produced by
pre-graduation pipelines keep loading. Production extracts always
write v1. The inner-image autocrop is computed at encode time and
doesn’t bump the schema – existing on-disk sidecars get autocropped
mp4s “for free” the next time export_video runs over them.
Inner-image autocrop
The panel ROI from AutoInt1’s GetUltrasoundX{1,2}/Y{1,2} is the
full B-mode panel: depth ruler + side margins + inner ultrasound
image + bottom-tick row. The depth ruler alone eats ~25% of the
panel width on single-probe acquisitions, and the bottom-tick row
pollutes the bottom with sharp non-anatomical contrast that confuses
DLC. We don’t want either in the per-panel mp4.
export_video runs a content-based detector against an aggregate of
16 evenly-spaced frames per panel and crops each mp4 to the inner
ultrasound image. Detection failures fall back to the outer panel
ROI with a warning. crop="panel" opts out explicitly.
Why at encode time, not extract time? Re-extraction requires
Admin EchoWave + Admin Python. The detector is offline (just needs
/frames/gray), and encoding is the slow stage anyway – ~50 ms of
detection vs. minutes of h265 lossless. Putting detection here
means detector tweaks only need a re-encode, not a re-extract.
Algorithm
Cols. Estimate the EchoWave UI gray level from the panel’s leftmost+rightmost five cols (taking the median to ignore the depth-ruler “0” digit’s bright pixels). A column is “margin” when its mean is within ~12 of that gray AND its vertical std is low (~12); the longest contiguous run of non-margin cols is the inner image width. Tick rows are pre-trimmed for this pass so a saturated bright stripe doesn’t poison the per-col std.
Rows. Walk up from the last panel row, peeling off rows whose col-restricted mean exceeds the tick threshold (
max(60, 2*median + 20)). Top edge of the inner image is the panel top (probed Telemed configurations place the depth-ruler “0” digit above the panel ROI’sy1).
Why content-based detection (not a probe-aperture lookup)
The probe-table approach (predict inner width from
probe_name + aperture_mm + image_d{x,y}_cm_per_px) was
sketched + dismissed 2026-05-24: predicted width was ~4-5% off
observed (670 vs 700 px on the LF9-5N60-A3 probe), meaning a
per-probe empirical correction table would be needed anyway. The
content-based detector self-calibrates from the actual pixels and
generalises to unfamiliar probes without a maintenance table.
For a fixed (probe, depth, view_area, panel_dims), the detected inner ROI is deterministic across recordings of the same acquisition config – a useful invariant for cross-file consistency audits.
Failure mode: fully-black / degenerate recordings
_detect_image_roi returns None when the gray-margin step isn’t
clear (no detectable inner-image bounds, or the resulting box is
< 20% of the panel area on either axis). The encoder falls back to
the panel ROI with a warning so the regression is visible.
Multi-probe auto-detection
A dual-probe acquisition lights up two B-mode panels side-by-side
(B + B2 in AutoInt1’s enum, img_id=1 + img_id=2). The authoritative
detection signal is the ROI enumeration itself: _collect_b_mode_rois
probes img_ids 1-4 and keeps every panel that returns a positive-area
rectangle. The number of populated ROIs = number of physical probes
in use.
Why not scanning_state (id 200)? It’s a useful sanity-check but
has undocumented sub-states. The 2026-05-24 pia02 probe reported
state=25, which isn’t in any documented id_state_bb_* constant.
The ROI count never ambiguates.
export_video follows: single-probe -> <stem>.mp4; dual-probe ->
<stem>_b1.mp4 + <stem>_b2.mp4.
Inactive-panel sentinel: (0, 0, 0, 0)
AutoInt1 returns the zero-rect sentinel (x1, x2, y1, y2) = (0, 0, 0, 0)
for inactive img_ids rather than raising. The 2026-05-24 metadata
probes on usl02 (single-probe) revealed B2/B3/B4 all coming back as
zero-rect. The TelemedRoi.from_cmd validator rejects anything that
isn’t a strict positive-area rectangle (x2 > x1 AND y2 > y1),
catching both the sentinel and any inverted/negative rect. Without
that fix, single-probe recordings would have been mis-classified as
quad-probe and produced four _b{N}.mp4 files (three of them
degenerate).
Encode pipeline: lossless h265 mono, ultrafast preset
Why lossless
The source /frames/gray is uint8 grayscale straight off the
beamformer – no upstream lossy step to reclaim quality from. A
CRF-tuned encode is buying file size at the cost of DLC accuracy that
the device gave us for free. The cropped per-panel ROI is small
enough (~700x550) that lossless h265 lands at ~3 GB per 20k-frame
recording, tolerable at corpus scale.
export_video(..., lossless=False, crf=N) is available as an opt-in
for users who’d rather trade a few percent of accuracy for ~50x
smaller files.
Why preset="ultrafast"
For lossless h265 the preset only trades file size against encode
decode speed – reconstructed pixels are bit-exact regardless.
ultrafastwins on every time axis (encode + linear decode + random seek + TOC build) at +6% size overfast, ~+15% overslow. Full bench table + methodology + raw numbers inBENCHMARKING.md. DLC inference is GPU-bound (~175 fps ceiling), so encoder preset is effectively neutral for inference; the decode + seek wins are what matter for interactive use (DUSTrack labeling, frame scrubbing).
Accuracy invariance: all four lossless presets produce DLC
predictions identical within float32 noise (max |delta| < 1e-4 px).
The lossy legacy h264/yuv420p path costs ~0.58 px median DLC keypoint
error and outliers up to 41 px – the lossless h265 mono pipeline
closes that gap. Parity bench data in
BENCHMARKING.md.
Dustrack UI fps: lossless h265 mono is ~22% faster in the
dustrack UI than legacy h264 yuv420p (42 fps vs 34 fps on the
encoding-axis adapter probe). Within the lossless presets the choice
is noise (~5% spread). Stacks with the existing fast_render Tier 2
architectural 3.94x gain from dustrack/BENCHMARKING.md.
Power-user overrides:
preset="slow"for the smallest lossless files (at ~7x slower encode + ~2x slower decode; accuracy-equivalent).lossless=False, crf=22for the smallest files at the ~0.6 px accuracy penalty (~50x smaller than lossless).
CPU vs GPU
We stick with CPU encoding (libx265). GPU options were investigated 2026-05-24 and rejected:
NVENC h264 has
-preset lossless/losslesshp, but h264 lossless of monochrome content runs 2-3x larger than h265 lossless, and NVENC typically convertsgraytoyuv420pwith synthetic chroma planes (defeats the chroma-free pipeline).NVENC h265 lossless support is inconsistent across drivers and often not bit-exact.
Other GPU paths (AMD VCN, Intel QSV) have similar limitations.
h264_nvenc -preset slow -rc constqp -qp 0 is fast and visually
indistinguishable from lossless for spot-checks, but it’s not
bit-exact and uses yuv420p – not a production output.
Orientation normalisation
EchoWave operators can toggle scan-direction (L/R flip) and rotation per machine. If different machines in a cohort save with different orientations, the same anatomy appears mirrored/rotated across recordings – catastrophic for cohort-wide DLC training.
The schema captures the L/R-flip state via b_is_scan_direction_changed
(AutoInt1 id 133, bool) and rotation via b_rotate (id 132, int).
export_video applies -vf hflip when the flip flag is True, so
every cohort mp4 lands in a canonical orientation regardless of
which operator toggled what on which machine. normalize_orientation=False
disables this for power-user inspection.
Known limitation: U/D flip
AutoInt1’s id_b_flip_up_down (105) is action-only – there’s no
companion getter. So U/D flip cannot be detected from the sidecar.
Mitigation: lock down the acquisition SOP (“never toggle U/D flip”) and visually spot-check representative frames per machine during cohort onboarding. If a U/D mismatch is found, the operator needs to either re-acquire or manually flag the affected recordings.
Known limitation: rotation enum
b_rotate returns an int (0/1/2/3? or actual degrees?) – the
AutoInt1 docs don’t specify the mapping. Both probed cohorts
(usl02, pia02) report 0. When a non-zero b_rotate is encountered,
_orientation_vf warns + leaves the pixels untouched; the user
should investigate and update the function once the mapping is
verified against a deliberately-rotated recording.
Spatial scale: physical (beamformer) vs image (display)
There are two scales to be aware of, and they differ by ~2% on typical Telemed acquisitions:
Attribute |
Returns |
Use for… |
|---|---|---|
|
beamformer-native sample spacing (from |
hardware provenance; not measurement |
|
display scale – |
cm conversions on tracked-point coords |
The reported physical_dx is the beamformer’s native radial sample
spacing – a function of the ADC clock and the assumed speed of sound.
But EchoWave renders the resulting image onto a display frame whose
height is laid out to match the operator-selected depth setting (the
depth ruler IS the trusted calibration). For a 50 mm depth setting
on a 558 px panel:
physical_dy_cm_per_px= 0.009166 cm/px (=> 558 × dy = 5.11 cm)image_dy_cm_per_px= 0.05 cm / 558 px = 0.00896 cm/px (=> 5.00 cm)
Per Telemed support: trust the depth setting. So image_d{x,y}
is what you want for spatial measurements on DLC keypoints. Both
attributes return None for v1 sidecars that lack params["b_depth"].
The display x scale is assumed equal to the y scale (image_dx == image_dy)
because Telemed renders with square display pixels (1:1 aspect so
anatomy doesn’t squish) and AutoInt1 reports physical_dx == physical_dy
on every probed acquisition. If a future probe breaks this
assumption it’ll surface as anatomy rendered with a non-1:1 aspect in
Log.view(); revisit then.
Timing
/timing/time_ms carries true per-frame timestamps at the device’s
native ~100 ns precision (Telemed acquisitions are VFR – the inter-
frame interval varies frame to frame around the mean fps; 50% of
frames land more than 1 ms off the mean). DLC and cv2 index by
frame number, so the encoded mp4 declares CFR at mean_fps – but
the .tvd.h5 is the source of truth for real time. Downstream
analysis converting tracked points back into the OT clock should
round-trip via Log.time_ms[frame_idx], not the mp4’s frame rate.
There is no timing CSV sidecar; an earlier design considered one, but it duplicates data already in the .tvd.h5 (and would risk desyncing).
Last-frame outlier
Both DICOM FrameTimeVector and the COM-extracted IFI show a ~0.078
ms inter-frame interval as the final entry on every recording –
recording-termination artifact (compound sub-frame). Harmless if
downstream sync work either drops the last frame or weights by IFI.
Per-session setup (Administrator EchoWave + Administrator Python)
The h5 stage (export_h5 / process) requires:
One-time per machine: install Echo Wave II (the Telemed vendor application). The AutoInt1 COM server ships inside it; the
Config\Pluginsfolder referenced below is created by the installer. There is nothing to download from this package for it.One-time per machine: register the COM ProgID. From an Administrator PowerShell:
cd "C:\Program Files\Telemed\Echo Wave II Application\EchoWave II\Config\Plugins" .\AutoInt1_regasm.bat
You should see “Types registered successfully”. Without this,
GetActiveObject('EchoWave2.CmdInt1')raises “Invalid class string”. (The exact install path can vary by EchoWave version / install location — ifConfig\Pluginsisn’t under that path, search the EchoWave install dir forAutoInt1_regasm.bat.)Per session: start EchoWave II as Administrator (right-click -> “Run as administrator”).
Per session: start your Python (or terminal) as Administrator. COM ROT publication is per-elevation; a non-elevated client can’t see an elevated server.
The video stage (export_video) is offline and runs in any Python.
Network drives
EchoWave’s OpenFile fails on UNC / mapped network paths in our
setup. export_h5 auto-detects non-C: drives + UNC prefixes, copies
each .tvd to a local temp dir, processes there, and copies the
resulting .h5 back to the source folder. A ThreadPoolExecutor
overlaps the network copies with the COM extraction
(stage N+1 + unstage N-1 run on workers while the COM thread handles
N).
Implementation notes
Pipe deadlock (libx265 + Popen)
libx265 prints per-frame statistics to stderr by default. Reading
frames from stdin via subprocess.Popen(..., stderr=PIPE) deadlocks
once the stderr buffer (~64 KB) fills – the encoder blocks waiting
for the reader, the Python frame loop blocks waiting for the encoder.
The cmd builder mandates -hide_banner -loglevel error so stderr
stays small enough to never fill.
pywin32 + .NET CCW: zero-arg methods are properties
AutoInt1’s zero-argument calls (GetFramesCount, GetCurrentFrameTime,
etc.) expose as properties under pywin32’s late binding, not
callables. Drop the parens:
n = cmd.GetFramesCount # works
n = cmd.GetFramesCount() # TypeError
Methods with arguments use normal parens. This bit the initial probe script; it’s wrapped inside the module now.
Acknowledgments